Title | Installation and maintenance manual for the extra strong rope pump for community wells |
Publication Type | Miscellaneous |
Year of Publication | 1995 |
Authors | Alberts, H, J. Gonzalez, G |
Pagination | 15 p.: tab., ill. |
Date Published | 1995-01-01 |
Publisher | Bombas de Mecate |
Place Published | Managua, Nicaragua |
Keywords | chain pumps, construction, design, maintenance, manuals, rope-and-washer pumps, well covers |
Abstract | The extra strong rope pump is designed for community wells serving more than five families, for irrigation, or for watering of more than 50 head of cattle. This manual provides technical specifications on pumping capacity, pipe diameters and well covers (both wooden and concrete). It also gives a step by step guide on installation of the rope pump. The final section of the manual covers pump maintenance and repair. |
Notes | Transl. of: Manual de instalacion y mantenimiento de la bomba de mecate extra fuerte, 1994 (isn 12253) |
Custom 1 | 232.2 |
Original Publication | Manual de instalacion y mantenimiento de la bomba de mecate extra fuerte |